VEGA VEGASON 63 4 … 20 mA_HART - four-wire User Manual

Page 42

Advertising
background image

42

10 Supplement

VEGASON 63 • 4 … 20 mA/HART - four-wire

28780-EN-130417

Process conditions
Process pressure

Ʋ with compression flange

-20 … 100 kPa/-0.2 … 1 bar (-2.9 … 14.5 psi)

Ʋ with mounting strap

0 kPa, since no seal possibility

Process temperature (transducer tem-

perature)

-40 … +80 °C (-40 … +176 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

8)

Electromechanical data - version IP 66/IP 67
Cable entry

Ʋ Double chamber housing

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5; plug M12 x 1 for VEGADIS 61

(optional)

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT, plug

M12 x 1 for VEGADIS 61 (optional)

or:

– 1 x plug (depending on the version), 1 x blind plug

M20 x 1.5; plug M12 x 1 for VEGADIS 61 (optional)

Spring-loaded terminals for wire cross-

section

< 2.5 mm² (AWG 14)

Display and adjustment module
Voltage supply and data transmission

through the sensor

Indication

LC display in dot matrix

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the sensor without cover IP 40

Material

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

Voltage supply
Operating voltage

Ʋ Non-Ex and Ex-d instrument

20 … 72 V DC, 20 … 253 V AC, 50/60 Hz

Power consumption

max. 4 VA; 2.1 W

Electrical protective measures
Protection rating

IP 66/IP 67

Overvoltage category

III

Protection class

I

8)

Tested according to the guidelines of German Lloyd, GL directive 2.

Advertising