Fig. 3: Inflowing material

VEGAVIB 67 can be mounted with a lock fitting for height

adjustment. Take note of the pressure information of the lock

fitting.

The vibrating element should protrude into the vessel to avoid

buildup. For that reason, avoid using mounting bosses for

flanges and screwed fittings. This is mainly applicable for

adhesive products.

In silos for bulk solids, material cones can form and change the

switching point. Please keep this in mind when installing the

sensor in the vessel. We recommend selecting an installation

location where the tuning fork detects an average value of the

material cone.
The tuning fork must be mounted at a location that takes the

arrangement of the filling and emptying apertures into account.
To compensate measurement errors caused by the material

cone in cylindrical vessels, the sensor must be mounted at a

distance of d/6 from the vessel wall.