3 Product description

VEGACAL 64 • 4 … 20 mA/HART - two-wire

30030-EN-130917

You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Screwed flanges are available in different versions according to the

following standards: DIN 2501, EN 1092-1, BS 10, ANSI B 16.5,

JIS B 2210-1984, GOST 12821-80.
You can find additional information in the supplementary instructions

manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID

31088).

Condensation

In case of strong condensation, the draining of condensed water

can change the measurement accuracy. The suitable version is the

Screening against condensation. The condensation can drain off

outside on the screening tube adapter.
Typical applications of the screening tube adapters are e.g. for

condensation or sockets. Apart from the standard version, there is

a second version for vacuum with a sepcial seal. When the screen-

ing tube adapter is submerged in liquid, we recommend the use of a

vacuum-tight version.
Socket

In case of long sockets, the screening tube can increase the sensitiv-

ity of the probe by compensating the influences of the socket. The

suitable version is Capacitive screening, vacuum-tight.
When the probe is mounted laterally, buildup can accumulate in the

socket. A screening tube makes the covered part of the probe inactive

and hence insensitive to influence from buildup and socket. Hence,

the screening tube adapter excludes changing influences caused by

the medium and ensures stable measurement conditions. The suit-

able version is Capacitive screening, vacuum-tight.

Protective cap

Flanges

Screening tube adapter