4.3 Mounting instructions

W

hen mounting VEGASON 64, keep a distance of at least 500 mm

(19.69

in) to the vessel wall. If the sensor is installed in the center of

dished or round vessel tops, multiple echoes can arise. These can,
however, be suppressed by an appropriate adjustment (see chapter
"

Setup").

I

f you cannot keep this distance you should carry out a false echo

storage before setup. This applies mainly if buildup on the vessel wall
is expected. In this case, we recommend repeating a false echo
storage later with existing buildup.

1

> 500 mm

Fig. 10: Mounting position
1

Reference plane

Mounting position