background image

Reference conditions to measuring accuracy (similar to DIN EN 60770-1)

Reference conditions according to DIN EN 61298-1

-

Temperature

+

18 … +30 °C (+64 … +86 °F)

-

Relative humidity

45 … 75 %

-

Air pressure

860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)

Other reference conditions

-

Reflector

ideal reflector, e.g. metal plate 2 x 2 m

-

False reflections

Biggest false echo, 20 dB smaller than the useful
echo

Characteristics and performance data

Frequency

C-band (6 GHz technology)

Step response or adjustment time

8)

>

1 s (dependent on the parameter setting)

Max. level change

adjustable up to 1 m/min. (dependent on the
parameter adjustment)

Max. emitted HF power of the antenna system

-

Pulse peak power approx.

0.1 mW

-

Pulse duration

<

2 ns

-

SAR value

9)

0.471 mW/kg

Measuring accuracy

Resolution, general

max. 1 mm (0.039 in)

Deviation

10)

see diagrams

0,5 m

(1.6 ft)

5,85 m

(19.19 ft)

10 mm (0.394 in)

5 mm (0.197 in)

- 5 mm (- 0.197 in)

- 10 mm (- 0.394 in)

0

Fig. 24: Deviation VEGAPULS 66 standpipe

8)

Time to output the correct level (with max. 10 % deviation) after a sudden
level change.

9)

at the aperture of a horn antenna with ø 150 mm

10)

Incl. non-linearity, hysteresis and non-repeatability.