VEGA VEGASWING 61 - contactless electronic switch User Manual

Page 25

Advertising
background image

25

9 Supplement

VEGASWING 61 • - contactless electronic switch

29223-EN-130409

Ʋ Standard

R

a

3 µm (1.18

-4

in)

Ʋ Hygienic version (3A)

R

a

< 0.8 µm (3.15

-5

in)

Ʋ Hygienic version (3A)

R

a

< 0.3 µm (1.18

-5

in)

Process fittings

Ʋ Pipe thread, cylindrical (DIN 3852-A) G¾, G1 A

Ʋ American pipe thread, conical

(ASME B1.20.1)

¾ NPT, 1 NPT

Ʋ Flanges

DIN from DN 25, ANSI from 1"

Ʋ hygienic fittings

Bolting DN 40 PN 40, Clamp 1" DIN 32676

ISO 2852/316L, Clamp 1½" PN 10 DIN 32676

ISO 2852/316L, conus DN 25 PN 40, Tuchenhagen

Varivent DN 50 PN 10

Max. torque - process fitting

Ʋ Thread G¾, ¾ NPT

75 Nm (55 lbf ft)

Ʋ Thread G1, 1 NPT

100 Nm (73 lbf ft)

Output variable
Output

Contactless electronic switch

Modes (switchable)

Ʋ A

Max. detection or overflow/overfill protection

Ʋ B

Min. detection or dry run protection

Accuracy (according to DIN EN 60770-1)
Reference conditions and actuating variables according to DIN EN 61298-1

Ʋ Ambient temperature

+18 … +30 °C (+64 … +86 °F)

Ʋ Relative humidity

45 … 75 %

Ʋ Air pressure

860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)

Ʋ Product temperature

+18 … +30 °C (+64 … +86 °F)

Ʋ Product density

1 g/cm³ (0.036 lbs/in³) (water)

Ʋ Product viscosity

1 mPa s

Ʋ Superimposed pressure

0 kPa

Ʋ Sensor installation

Vertically from top

Ʋ Density selection switch

> 0.7 g/cm³

Measuring accuracy
Deviation

± 1 mm (0.04 in)