VEGA VEGAPULS 67 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual

Page 21

Advertising
background image

be a place where no installations cross the microwave signals. Make
sure when planning your measurement loop that the radar signals
have a "clear view" to the product.

I

n case of existing vessel installations, a false echo storage should be

carried out during setup.

I

f large vessel installations such as struts or supports cause false

echoes, these can be attenuated through supplementary measures.
S

mall, inclined sheet metal baffles above the installations scatter the

radar signals and prevent direct interfering reflections.

Fig. 15: Cover smooth profiles with deflectors

A

ir rinsing is useful for avoiding buildup, particularly when there is

strong condensation. Since VEGAPULS 67 has no direct rinsing air
connection, a separate rinsing air connection must be provided in the
mounting socket. By inclining this connection towards the top, a
particularly effective cleaning of the antenna cover is achieved.

Fig. 16: Purging air connection

L

arge material heaps are best measured with several instruments,

which can be mounted on e.g. traverse cranes. For this type of
application it is advantageous to orient the sensor perpendicular to the
bulk solid surface.

T

he sensors do not influence each other.

Information:
K

eep in mind that for these applications, the sensors are designed for

relatively slow level changes. If the sensor is used on a movable boom,

Air rinsing

Material heaps

VEGAPULS

67 • 4 … 20

mA/HART four-wire

21

4 M

ounting

32939

-EN

-100514

Advertising