10 supplement, 1 technical data, 10 .1 technical data – VEGA VEGAPULS 67 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual

Page 48

Advertising
background image

10

Supplement

10

.1 Technical data

General data

316L

corresponds to 1.4404 or 1.4435

M

aterials, wetted parts

-

H

orn antenna

PBT-GF30

-

F

ocussing lens

PP

-

A

dapter flange

PPH

-

S

eal, adapter flange

FKM (V

iton)

M

aterials, non-wetted parts

-

H

ousing

A

luminium die-casting powder coated

-

S

eal between housing and housing

cover

NBR (

stainless steel housing), silicone (Alu/plastic

housing)

-

I

nspection window in housing cover for

PLICSCOM

P

olycarbonate (UL-746-C listed)

-

G

round terminal

316T

i/316L

M

ax. torque, mounting screws - strap on the

sensor housing

4 N

m (2.95 lbf ft)

W

eight, depending on housing material and

version

0.7 … 3.4

kg (1.543 … 7.496 lbs)

Output variable

O

utput signal

4 … 20

mA/HART (active)

C

ycle time

min. 1 s (dependent on the parameter setting)

S

ignal resolution

1.6 µA

F

ailure signal current output (adjustable)

mA value unchanged 20.5 mA, 22 mA, < 3.6 mA
(

adjustable)

M

ax. output current

22

mA

L

oad

<

500 Ω

3)

D

amping (63 % of the input variable)

0 … 999

s, adjustable

F

ulfilled NAMUR recommendations

NE

43

HART

output values

-

1. HART

value (Primary Value)

D

istance to the level

-

2. HART

value (Secondary Value)

D

istance to the level - scaled (for example hl, %)

R

esolution, digital

>

1

mm (0.039 in)

Input variable

M

easured variable

3)

W

ith inductive load ohmic share min. 25 Ω/mH.

48

VEGAPULS

67 • 4 … 20

mA/HART four-wire

10 S

upplement

32939

-EN

-100514

Advertising