4 Mounting

4.1 Mounting instructions

If the electronics module is defective, it can be replaced by the

user.

In Ex applications, only an instrument and an electronics

module with appropriate Ex approval may be used.

4.2 Mounting preparations

In general, all oscillators of series WE 60 can be interchanged.

If you want to use an oscillator with a different signal output,

you can download the corresponding operating instructions

manual from our homepage under Downloads.

4.3 Mounting steps

Proceed as follows to exchange the electronics module:
1 Switch off power supply
2 Unscrew the housing cover
3 Lift the opening levers of the terminals with a screwdriver
4 Pull the connection cables out of the terminals
5 Loosen the two screws with a screw driver (Torx size T10

or slot 4)

2

1

Fig. 1: Loosen the screws

1

Electronics module

2

Screws (2 pcs.)

6 Remove the old oscillator