3 exchange of the electronics module – VEGA VEGACAP 69 - two-wire User Manual

Page 21

Advertising
background image

21

7 Maintenance and fault rectification

VEGACAP 69 • - two-wire

31177-EN-130916

1 2

3

Fig. 13: Check the resistance in the probe
1 Shielding

2 Probe

3 Ground potential

Depending on the reason for the fault and the measures taken, the

steps described in chapter "Set up" may have to be carried out again.

7.3 Exchange of the electronics module

In general, all electronics modules of series CP60 can be inter-

changed. If you want to use an electronics module with a different

signal output, you can download the corresponding operating instruc-

tions manual from our homepage under Downloads.
Proceed as follows:
1. Switch off power supply
2. Unscrew the housing cover
3. Lift the opening levers of the terminals with a screwdriver
4. Pull the connection cables out of the terminals
5. Loosen the two screws with a screw driver (Torx size T10 or slot

4)

Reaction after fault recti-

fication

Advertising