VEGA VEGAWAVE 62 - Relay (DPDT) User Manual

Page 26

Advertising
background image

Sensor length (L) - suspension cable FEP
(-40 … +150 °C/-40 … +302 °F)

0.6 … 80 m (1.969 … 262.47 ft)

Output variable

Output

Relay output (DPDT), 2 floating spdts
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Turn-on voltage

-

Min.

10 mV

-

Max.

253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Switching current

-

Min.

10 µA

-

Max.

3 A AC, 1 A DC

Breaking capacity

-

Min.

50 mW

-

Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

min./max.

Switching delay

-

When immersed

0.5 s

-

When laid bare

1 s

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of solids

Process pressure

-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psig)

Process temperature with PUR suspension
cable

-20 … +80 °C (-4 … +176 °F)

Process temperature with FEP suspension
cable

-40 … +150 °C (-40 … +302 °F)

Product density

-

Standard

>

0.02 g/cm³ (0.0007 lbs/in³)

-

adjustable

>

0.008 g/cm³ (0.0003 lbs/in³)

26

VEGAWAVE

62 • - Relay (DPDT)

9 Supplement

32252

-EN

-120418