10 Supplement

PLICSRADIO R61 • Wireless receiving unit (single channel)

32625-EN-130228

Ʋ Standard version

4 dBi

Ʋ Version increased range

1.3 dBi

Display and adjustment module
Voltage supply and data transmission

through PLICSRADIO via gold-plated sliding contacts

(I²C bus)

Indication

LC display in dot matrix

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the sensor without cover IP 40

Materials

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

Electromechanical data
Cable entry/plug

Ʋ Housing socket

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 2 x

blind plug M20 x 1.5

or:

– 1 x closing cap ½ NPT, 2 x blind plug ½ NPT

Ʋ Electronics housing

– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

antenna connection (R-SMA)

or:

– 1 x closing cap ½ NPT, 1 x antenna connection

(R-SMA)

Spring-loaded terminals

for wire cross-section up to 2.5 mm² (AWG 14)

Ambient conditions
Ambient, storage and transport tempera-

ture

-40 … +80 °C (-40 … +176 °F)

Electrical protective measures
Protection rating

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing

IP 66/IP 67

3)

Overvoltage category

III

Protection class depending of the power supply unit version

Ʋ 24 V version

II

Ʋ 115/230 V version

I

Electrical separating measures
Reliable separation according to VDE 0106 part 1 between power supply and input

Ʋ Reference voltage

253 V (50 V at 24 V power supply unit version)

3)

A suitable cable is the prerequisite for maintaining the protection rating.