9 supplement, 1 technical data – VEGA VEGACAL External housing User Manual

Page 15

Advertising
background image

15

9 Supplement

External housing • VEGACAP, VEGACAL

31085-EN-130916

9 Supplement

9.1 Technical data

Technical data
Following you find all data deviating from the standard instrument. All other technical data are

specified in the operating instruction of the respective sensor.
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, non-wetted parts

Ʋ Sensor housing - metal housing IP 68

(10 bar)

316L

Ʋ Sensor housing - metal housing IP 67 316L

Ʋ Sensor housing - BNC plug IP 54

316L

Ʋ External housing (instrument housing) plastic PBT (Polyester)

Ʋ Housing socket

plastic PBT (Polyester)

Ʋ Wall mounting plate

plastic PBT (Polyester)

Ʋ Seal between housing socket and wall

mounting plate

TPE (fixed connected)

Ʋ Seal between housing and housing

cover (instrument version)

Silicone

Ʋ Ground terminal

316L

Ʋ Connection cable

FEP

Weights

Ʋ External plastic housing

660 g (23 oz)

Ʋ Sensor housing - IP 68 (10 bar)

1100 g (38 oz)

Ʋ Sensor housing - IP 67

400 g (14.1 oz)

Ʋ Sensor housing - IP 54

190 g (6.7 oz)

Process fittings

Ʋ Sensor housing - IP 68 (10 bar)

G¾, ¾ NPT, G1, 1 NPT, G1½, 1½ NPT

Ʋ Sensor housing - IP 67

G½, ½ NPT

Ʋ Sensor housing - IP 54

G½, ½ NPT

Cable length to the external housing

2 … 10 m (6.562 … 32.81 ft)

Process conditions
Process pressure

-1 … 63 bar/-100 … 6400 kPa (-14.5 … 928 psig)

Process temperature

Depending on the sensor

Ambient temperature on the sensor

housing

-50 … +150 °C (-58 … +302 °F)

Ambient temperature on the sensor

housing - with BNC plug connection

-50 … +100 °C (-58 … +212 °F)

Ambient temperature on the connection

cable

-50 … +150 °C (-58 … +302 °F)

Ambient, storage and transport temperature on the instrument housing

Advertising