VEGA VEGACAP 69 - Relay (DPDT) User Manual

Page 27

Advertising
background image

27

9 Supplement

VEGACAP 69 • - Relay (DPDT)

31175-EN-130916

Ʋ Min.

50 mW

Ʋ Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched

through, the gold plating on the relay contact surface will

be permanently damaged. The contact is then no longer

suitable for switching low-level signal circuits.

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

Min./Max.

Switching delay

Ʋ When immersed

0.7 s

Ʋ When laid bare

0.7 s

Ʋ In case of failure

1 s

Ambient conditions
Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions
Process pressure

-1 … 2 bar/-100 … 200 kPa (-14.5 … 29 psig)

Process temperature

Ʋ Flange of PTFE

-40 … +100 °C (-40 … +212 °F)

Ʋ Flange of PP

0 … +60 °C (+32 … +140 °F)

45°C

100°C

1

-1

0

2

0°C

-40°C

1

2

Fig. 30: Process pressure - Process temperature (flange of PTFE)
1 Process pressure

2 Process temperature