9 Supplement

VEGACAP 69 • - Relay (DPDT)

31175-EN-130916

Voltage supply
Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at

U >60 V DC, the ambient temperature can be max.

50 °C/122 °F)

Power consumption

1 … 8 VA (AC), approximately 1 W (DC)

Electrical protective measures
Protection rating

IP 66/IP 67

Overvoltage category

III

Protection class

I

Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-

ments without SIL qualification ex factory, the functional safety must be activated by the user via

the display and adjustment module or via PACTware for applications according to SIL.

Functional safety according to IEC 61508-4

Ʋ Single channel architecture (1oo1D) up to SIL2

Ʋ double channel diversitary redundant

architecture (1oo2D)

up to SIL3

You can find detailed information in the supplied Safety Manual of the instrument series or under

"www.vega.com", "Downloads", "Approvals".

9.2 Dimensions

VEGACAP 69, housing

3

2

1

4

~ 69 mm

(2.72")

ø 79 mm

(3.11")

117 mm (4.61"

)

M20x1,5/

½ NPT

~ 59 mm

(2.32")

ø 80 mm

(3.15")

112 mm (4.41"

)

M20x1,5/

½ NPT

~ 69 mm

(2.72")

ø 79 mm

(3.03")

112 mm (4.41"

)

M20x1,5/

½ NPT

~ 116 mm (4.57")

ø 86 mm (3.39")

11

6 mm (4.57"

)

M20x1,5

M20x1,5/

½ NPT

Fig. 32: Housing versions
1 Plastic housing

2 Stainless steel housing, electropolished

3 Stainless steel housing, precision casting

4 Aluminium housing