2 principle of operation – VEGA VEGAFLEX 66 (-20…+250°C) 4 … 20 mA_HART four-wire User Manual

Page 8

Advertising
background image

1
2

3

Fig. 1: VEGAFLEX 66 - cable version with double chamber housing

1

Housing cover with integrated indicating and adjustment module (optional)

2

Housing with electronics

3

Process fitting

T

he type label contains the most important data for identification and

use of the instrument:

l

A

rticle number

l

S

erial number

l

T

echnical data

l

A

rticle numbers, documentation

l

SIL

identification (with SIL rating ex works)

W

ith the serial number, you can access the delivery data of the

instrument via www.vega.com, "VEGA Tools" and "serial number
search
". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.

3

.2 Principle of operation

VEGAFLEX

66

is a level sensor with coax, rod or cable probe for

continuous level measurement in products with temperatures between
-20 °C

and +250 °C (-4 … +482 °F).

I

t is designed for industrial use in all areas of process technology and

can be used in liquids.

H

igh frequency microwave pulses are guided along a steel rope or a

rod. Upon reaching the product surface, the microwave pulses are
reflected. The running time is evaluated by the instrument and
outputted as distance.