3 wiring plan, 5 set up, 1 setup steps – VEGA VEGABAR S 14 User Manual

Page 19: 5 s et up

Advertising
background image

Information:
Note the correct arrangement, see illustra-
tion

9

Tighten the screws on the strain relief and
cable entry

10 H

ook in the cover and push onto the plug

connection, tighten cover screw

11 P

lug the plug insert with seal to VEGABAR S

14

and tighten the screw

The electrical connection is finished.

4

.3

Wiring plan

Angled plug connector according to ISO 4400

1

2

3

+

-

1

Fig. 15: Version: Electrical connection "Y", view to the connection on
the instrument side

1

Voltage supply and signal output

Round plug connector M12 x 1

3

+

-

1

3

2

4

1

Fig. 16: Version: Electrical connection "M", view to the connection on
the instrument side

1

Voltage supply and signal output

5 S

et up

5

.1

Setup steps

After mounting and electrical connection, VEGA-
BAR S 14 is ready for operation.

VEGABAR S 14 delivers a current of 4 … 20 mA
corresponding to the actual process pressure.

Further settings are not necessary.

VEGABAR S 14

19

Set up

32950

-

01

-

101123