2 mounting steps with straining clamp, 3 mounting steps with screwed connection – VEGA VEGAWELL S 51 User Manual

Page 17

Advertising
background image

Information:
For this purpose, we recommend
VEGABOX 02. It contains terminals and a

lter element for pressure compensation. A

suitable protective cover is available for
outdoor mounting.

Mounting example

Fig. 10: Mounting example: VEGAWELL S 51 in a pump shaft with
breather housing VEGABOX 02

3

.2

Mounting steps with straining clamp

2

3

1

Fig. 11: Straining clamp

1

Suspension cable

2

Suspension opening

3

Clamping jaws

Mount VEGAWELL S 51 with straining clamp as
follows:

1

Hang the straining clamp on a suitable wall
hook

2

Lower VEGAWELL S 51 to the requested
height

3

Slide the clamping jaws upward and push the
suspension cable between them

4

Hold the suspension cable, push the clamping
jaws downward and fix them with a light blow

Removal is carried out in reverse order.

3

.3

Mounting steps with screwed
connection

1

2

3

4

5

6

Fig. 12: Threaded fitting

1

Suspension cable

2

Seal screw

3

Cone bushing

4

Seal cone

5

Threaded fitting

6

Seal

Mount VEGAWELL S 51 with screwed connection
as follows:

1

Weld the welded socket into the vessel top

2

Lower VEGAWELL S 51 to the requested
height by means on the welded socket G1½ A
or 1½ NPT on the vessel side

3

Insert the suspension cable from below into the
open screwed connection

4

Slide the seal cone and the cone sleeve over
the suspension cable, fasten manually with the
seal screw

5

Screw the screwed connection into the socket,
fasten with SW 30 and then fasten seal screw
with SW 19

How to correct the height:

1

Loosen seal screw with SW 19

VEGAWELL S 51

17

Mounting

32946

-

01

-

101123

Advertising