Output variable

Output

Two-wire NAMUR output

Current consumption

-

Falling characteristics (max.)

2.4 mA uncovered/≤ 1 mA covered

-

Rising characteristics (min.)

1 mA uncovered/≥ 2.4 mA covered

-

Fault message

1 mA

Necessary processing system

NAMUR processing system according to
IEC

60947-5-6 (EN 50227/DIN 19234)

Modes (NAMUR output adjustable to falling or rising characteristics)

-

Min.

rising characteristic curve (High current when
immersed)

-

Max.

falling characteristics (Low current when immersed)

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of solids

Process pressure

-1 … 25 bar/-100 … 2500 kPa (-14.5 … 363 psig)

VEGAWAVE

61 of 316L

-50 … +150 °C (-58 … +302 °F)

Process temperature (thread or flange tem-
perature) with temperature adapter (option)

-50 … +250 °C (-58 … +482 °F)

1

2

3

-50°C

(-58°F)

50°C

(122°F)

40°C

(104°F)

-40°C

(-40°F)

80°C

(176°F)

0°C

(32°F)

100°C

(212°F)

150°C

(302°F)

200°C

(392°F)

250°C

(482°F)

Fig. 32: Ambient temperature - Process temperature

1

Process temperature

2

Ambient temperature

3

Temperature range with temperature adapter

30

VEGAWAVE

61 • - NAMUR

9 Supplement

32249

-EN

-120418

Advertising