VEGA VEGAFLEX 67 (-200…+400°C) 4 … 20 mA_HART four-wire User Manual

Page 49

Advertising
background image

L

0

-10 mm (-0.394

")

10 mm (0.394

")

0,1 m (3.937

"

)

0,15 m

(1.968

")

1

1

Fig. 22: Deviation VEGAFLEX 67 in coax version

1

Dead zone - no measurement possible in this area

L

Probe length

Influence of the ambient temperature to the sensor electronics

T

emperature drift

0.03 %/10 K

relating to the max. measuring range

or max. 0.3 %

T

emperature drift - Digital output

3

mm/10 K relating to the max. measuring range or

max. 10 mm

Ambient conditions

A

mbient, storage and transport temperature

-

40 … +80 °C (-40 … +176 °F)

Process conditions

P

rocess pressure

-

1 … +400

bar/-100 … +40000 kPa (-

-

14.5 … +5800

psig), depending on the process

tting

VEGAFLEX

67 • 4 … 20

mA/HART - four-wire

49

10 S

upplement

32312

-

EN

-120329