4 connecting to power supply, 1 preparing the connection, 2 connection procedure – VEGA VEGAVIB S 61 User Manual

Page 15: 4 c onnecting to power supply

Advertising
background image

Filling opening
Mount the instrument in such a way that the
vibrating rod does not protrude directly into the

lling stream.

Horizontal mounting

20°

a.

b.

Fig. 10: Horizontal mounting

a

Protective sheet

b

Concave protective sheet for abrasive solids

4 C

onnecting to power supply

4

.1

Preparing the connection

Note safety instructions
Always keep in mind the following safety instruc-
tions:

l

Connect only in the complete absence of line
voltage

l

Take note of safety instructions for Ex appli-
cations

Select power supply
Connect the power supply according to the
following diagrams. Oscillator VB60R is designed
in protection class 1. To maintain this protection
class, it is absolutely necessary that the ground
conductor be connected to the internal ground
terminal. Take note of the general installation
regulations. As a rule, connect VEGAVIB S 61 to
vessel ground (PA), or in case of plastic vessels, to
the next ground potential. On the side of the
housing there is a ground terminal between the
cable entries. This connection serves to drain off
electrostatic charges. In Ex applications, the
installation regulations for hazardous areas must
be given priority.

The data for voltage supply are specified in chapter
"Technical data" in the "Supplement".

Selecting connection cable
VEGAVIB S 61 is connected with standard four-
wire cable with round cross-section. An outer cable
diameter of 5 … 9 mm ensures the seal effect of
the cable entry.

If cable with a different diameter or wire cross
section is used, exchange the seal or use an
appropriate cable connection.

4

.2

Connection procedure

Proceed as follows:

1

Unscrew the housing cover

2

Loosen compression nut of the cable entry

3

Remove approx. 10 cm (4 in) of the cable
mantle, strip approx. 1 cm (0.4 in) insulation
from the ends of the individual wires

4

Insert the cable into the sensor through the
cable entry

5

Lift the opening levers of the terminals with a
screwdriver (see following illustration)

6

Insert the wire ends into the open terminals
according to the wiring plan

7

Press down the opening levers of the termi-
nals, you will hear the terminal spring closing

8

Check the hold of the wires in the terminals by
lightly pulling on them.

9

Tighten the compression nut of the cable entry.
The seal ring must completely encircle the
cable

10

If necessary, carry out a fresh adjustment

11

Screw the housing cover on

The electrical connection is finished.

VEGAVIB S 61

15

Connecting to power supply

32796

-

01

-

080108

Advertising