VEGA VEGAWAVE 63 - two-wire User Manual
Page 33
Fig. 48: Max. lateral load alongside fork side (narrow fork side)
Output variable
Output
Two-wire output
Suitable signal conditioning instruments
VEGATOR
536Ex, 537Ex, 636Ex
Output signal
-
Mode min.
Vibrating element uncovered: 16 mA ±1 mA,
vibrating element covered: 8 mA ±1 mA
-
Mode max.
Vibrating element uncovered: 8 mA ±1 mA, vibrat-
ing element covered: 16 mA ±1 mA
-
Fault message
<
2.3 mA
Modes (switchable)
min./max.
Switching delay
-
When immersed
0.5 s
-
When laid bare
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of solids
Process pressure
-1 … 25 bar/-100 … 2500 kPa (-14.5 … 363 psig)
VEGAWAVE
63 of 316L
-50 … +150 °C (-58 … +302 °F)
Process temperature (thread or flange tem-
perature) with temperature adapter (option)
-50 … +250 °C (-58 … +482 °F)
VEGAWAVE
63 • - two-wire
33
9 Supplement
32260
-
EN
-120418