4 Mounting
External housing • For pressure transmitter VEGABAR
31087-EN-130322
2
1
Fig. 3: Loosen the holding screws of the electronics module
1 Electronics module
2 Screws (2 pcs.)
5. Pull the electronics out by holding the opening levers.
To dismount the electronics module from the new housing, proceed
as follows:
1. Insert the electronics module carefully into the new housing.
Information:
The electronics module is connected via a plug. Make sure that the
plug is in the correct position. The marking notch must be in position
"18.00 h".
1
Fig. 4: Plug position in the base of the external housing
1 Notch
2. Screw in and tighten the two screws with the screwdriver.
3. Screw the housing cover back on
The exchange of the electronics module is finished.
As a rule, an exchange of electronics must be documented internally
when Ex applications are involved.
4.3 Mounting steps, external housing
1. Mark the holes according to the following drilling template
Mounting the electronics
module
Wall mounting - External
housing