VEGA VEGABAR 54 Profibus PA User Manual
Page 46
46
10 Supplement
VEGABAR 54 • Profibus PA
36729-EN-130321
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
0 … 1 bar/0 … 100 kPa
35 bar/3500 kPa
0 bar abs.
0 … 2.5 bar/0 … 250 kPa
50 bar/5000 kPa
0 bar abs.
0 … 5 bar/0 … 500 kPa
65 bar/6500 kPa
0 bar abs.
0 … 10 bar/0 … 1000 kPa
90 bar/9000 kPa
0 bar abs.
0 … 25 bar/0 … 2500 kPa
130 bar/13 MPa
0 bar abs.
0 … 60 bar/0 … 6000 kPa
200 bar/20 MPa
0 bar abs.
Nominal measuring ranges and overload capability in psig
The specifications are only an overview and refer to the measuring cell. Limitations due to the ma-
terial and version of the process fitting are possible. The specifications on the nameplate apply.
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 … +1.5 psig
+200 psig
-3 psig
0 … +3 psig
+290 psig
-6 psig
0 … +6 psig
+430 psig
-12 psig
0 … +15 psig
+500 psig
-15 psig
0 … +35 psig
+725 psig
-15 psig
0 … +70 psig
+950 psig
-15 psig
0 … +150 psig
+1300 psig
-15 psig
0 … +350 psig
+1900 psig
-15 psig
0 … +900 psig
+2900 psig
-15 psig
-15 … 0 psig
+500 psig
-15 psig
-15 … +25 psig
+700 psig
-15 psig
-15 … +70 psig
+950 psig
-15 psig
-15 … +150 psig
+1300 psig
-15 psig
-15 … +350 psig
+1900 psig
-15 psig
-15 … +900 psig
+2900 psig
-15 psig
-0.7 … +0.7 psig
+200 psig
-3 psig
-1.5 … +1.5 psig
+290 psig
-6 psig
-3 … +3 psig
+430 psig
-12 psig
-7 … +7 psig
+500 psig
-15 psig
Absolute pressure
0 … 15 psi
500 psi
0 psi
0 … 35 psi
700 psi
0 psi
0 … 70 psi
900 psi
0 psi
0 … 150 psi
1300 psi
0 psi
0 … 350 psi
1900 psi
0 psi