4.3 Instructions for installation
l
Suitable seals must be selected for sealing
l
For flange mounting, use a seal with a sufficiently large inner
diameter and place the seal centrically; contact with the diaphragm
will cause measurement deviations
l
When using soft material or PTFE seals, take note of the
regulations of the seal manuffacturer, particularly with respect to
torque and settling cycles
l
Lay in vibration-free areas to avoid additional pressure fluctuations
l
Do not lay close to heating or cooling lines
l
Insulate in case of colder or warmer ambient temperatures
l
Bending radius of the capillaries ≥ 150 mm
Sealing
Laying the capillaries
10
Chemical seal CSS • for VEGADIF 65
4 Mounting
36134