Fig. 2: Recommended vessel insulation with chemical seal without cooling area
(length 100 mm)

1

Vessel wall

2

Vessel insulation

3

VEGADIF 65

4

Chemical seal

If a suitable insulation of the vessel is not possible, use a chemical seal
with cooling area (length 150 mm).

4.2 Instructions for handling

l

Instruments must be protected against soiling and strong fluctua-
tions of the ambient temperature

l

Leave the measuring system in the packaging until mounting to
protect it against mechanical damages

l

When removing the packaging and when mounting, take special
care to avoid mechanical damage and deformation of the
diaphragm

l

Do not carry the pressure transmitter by holding the capillary line

l

Do not bent the capillary lines. Kinks can cause leakage and lead
to an increase in response time

l

Never loosen sealed screws on the chemical seal or the pressure
transmitter

l

Do not damage the isolating diaphragm: scratches on the isolating
diaphragm (e.g. from sharp subjects) are the main areas where
corrosion can occur