2 dimensions – VEGA VEGABAR 54 4 … 20 mA_HART - climate compensated User Manual

Page 57

Advertising
background image

57

10 Supplement

VEGABAR 54 • 4 … 20 mA/HART - climate compensated

36727-EN-130321

1000

750

500

250

12

18

16

14

20

22

24

26

28

30

32

34

36

V

4

1

2

3

Fig. 26: Voltage diagram
1 HART load with HART version

2 Voltage limit EEx-ia instrument

3 Voltage limit non-Ex instrument

4 Operating voltage

Electrical protective measures
Protection rating

Ʋ Housing, standard

IP 66/IP 67

16)

Ʋ Aluminium and stainless housing

(optionally available)

IP 68 (1 bar)

17)

Ʋ Process component in IP 68 version IP 68 (25 bar)

Ʋ External housing

IP 65, IP 66/IP 68 (0.2 bar)

Overvoltage category

III

Protection class

II

10.2 Dimensions

The following dimensional drawings represent only an extract of the possible versions. Detailed

dimensional drawings can be downloaded on www.vega.com under "Downloads" and "Drawings".
The two chamber housings are not available with instruments with 4 … 20 mA signal output

16)

Instruments with gauge pressure measuring ranges cannot detect the ambient pressure when submerged, e.g.

in water. This can lead to falsification of the measured value.

17)

Only with instruments with absolute pressure ranges.