VEGA VEGAPULS 65 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - four-wire User Manual
Page 22
22
5 Connecting to power supply
VEGAPULS 65 • 4 … 20 mA/HART - four-wire
36516-EN-121011
power supply
4...20mA
active
passive
common
IS GND
5
1
/L
/N
PE
2
+
( )
(-)
6 7
8
Fig. 15: Connection compartment with double chamber housing with mains
voltage
Terminal
Function
Polarity
1
Voltage supply
+/L
2
Voltage supply
-/N
5
4 … 20 mA output (active)
+
6
4 … 20 mA output (passive)
+
7
Mass - output
-
8
Function ground with installa-
tion according to CSA
power supply
4...20mA
active
passive
common
IS GND
5
1
/L
/N
2
+
( )
(-)
6 7
8
Fig. 16: Connection compartment with double chamber housing with low volt-
age
Terminal
Function
Polarity
1
Voltage supply
+/L
2
Voltage supply
-/N
5
4 … 20 mA output (active)
+
6
4 … 20 mA output (passive)
+
7
Mass - output
-
8
Function ground with installa-
tion according to CSA
Connection compartment
with mains voltage
Connection compartment
with low voltage