7 Setup with PACTware
VEGAPULS 65 • 4 … 20 mA/HART - four-wire
36516-EN-121011
7 Setup with PACTware
7.1 Connect the PC
3
1
2
Fig. 21: Connection of the PC directly to the sensor via the interface adapter
1 USB cable to the PC
2 Interface adapter VEGACONNECT 4
3 Sensor
Information:
The interface adapter VEGACONNECT 3 is not suitable for connec-
tion to the sensor.
1
5
2
4
3
OP
EN
TWIST
USB
LOCK
Fig. 22: Connecting the PC via HART to the signal cable
1 VEGAPULS 65
2 HART resistance 250 Ω (optional depending on processing)
3 Connection cable with 2 mm pins and terminals
4 Processing system/PLC/Voltage supply
Necessary components:
•
VEGAPULS 65
•
PC with PACTware and suitable VEGA DTM
•
VEGACONNECT 4
•
HART resistance approx. 250 Ω
Via the interface adapter
directly on the sensor
Connection via HART