5 accessories and replacement parts – VEGA VEGABAR 55 4 … 20 mA_HART User Manual

Page 10

Advertising
background image

10

3 Product description

VEGABAR 55 • 4 … 20 mA/HART

36734-EN-130321

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.5 Accessories and replacement parts

The display and adjustment module PLICSCOM is used for measured

value indication, adjustment and diagnosis. It can be inserted into the

sensor and removed at any time.
You can find further information in the operating instructions "Display

and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT 4 enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, an adjustment software

such as PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

VEGADIS 61 is suitable for external measured value indication and

adjustment of plics® sensors. It is connected to the sensor with an up

to 25 m long, four-wire, screened standard cable.
You can find further information in the operating instructions "VE-

GADIS 61" (Document-ID 27720).

VEGADIS 62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART

signal cable.
VEGADIS 62 is suitable for measured value indication with sensors

without HART protocol.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

Flanges are available in different versions according to the following

standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-1984,

GOST 12821-80.
You can find additional information in the supplementary instructions

manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID

31088).

The measuring instrument holder is used for wall/tube mounting of

VEGABAR series 50 pressure transmitters and VEGAWELL 52 sus-

pension pressure transmitters. Supplied reducers enable the adapta-

tion to different instrument diameters. The material used is 316L.

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Storage and transport

temperature

Display and adjustment

module

Interface adapter

External display and

adjustment unit

External display and ad-

justment unit VEGADIS 62

Flanges

Measuring instrument

holder

Protective cover