VEGA VEGABAR 55 4 … 20 mA_HART User Manual

Page 55

Advertising
background image

55

10 Supplement

VEGABAR 55 • 4 … 20 mA/HART

36734-EN-130321

Long-term stability (according to DIN 16086 and IEC 60770-1)
Applies to digital HART interface as well as to analogue current output 4 … 20 mA under refer-

ence conditions. Specifications refer to the set span. Turn down (TD) is the relation nominal meas-

uring range/set span.
Long-term drift of the zero signal:

Ʋ For one year

< 0.05 % x TD

Ʋ For five years

< 0.1 % x TD

Ʋ For ten years

< 0.2 % x TD

Ambient conditions
Ambient, storage and transport temperature

Ʋ Standard version

-40 … +80 °C (-40 … +176 °F)

Ʋ Versions IP 66/IP 68 (1 bar) and IP 68

(25 bar), connection cable PUR

-20 … +80 °C (-4 … +176 °F)

Ʋ Version IP 66/IP 68 (1 bar), connec-

tion cable PE

-20 … +60 °C (-4 … +140 °F)

Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The

specifications on the type label are applicable.
Pressure stage, process fitting

Ʋ Thread 316L, depending on connec-

tion

PN 25, PN 60

Ʋ Thread Aluminium

PN 25

Ʋ Hygienic fittings 316L, depending on

connection

PN 6, PN 10, PN 25, PN 40 (PN 40 only with DRD and

DIN 11851)

Ʋ Flange 316L

PN 16/PN 40 or 150 lb/300 lb

Product temperature

Ʋ Standard

-12 … +140 °C (+10 … +284 °F)

Ʋ with extenation, extended thread or

Clamp 2½"

-12 … +140 °C (+10 … +284 °F)

Ʋ with cooling element

-12 … +180 °C (+10 … +356 °F)

Ʋ with cooling element and screening

sheet

-12 … +200 °C (+10 … +392 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

12)

Shock resistance

Acceleration 100 g/6 ms

13)

Electromechanical data - version IP 66/IP 67
Cable entry/plug

14)

12)

Tested according to the guidelines of German Lloyd, GL directive 2.

13)

Tested according to EN 60068-2-27.

14)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.

Advertising