VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - four-wire User Manual

Page 20

Advertising
background image

20

4 Mounting

VEGAPULS 61 • 4 … 20 mA/HART - four-wire

36500-EN-121011

The socket piece should be dimensioned in such a way that the an-

tenna end protrudes at least 10 mm (0.4 in) out of the socket.

ca

. 10 mm

Fig. 15: Recommended socket mounting

If the reflective properties of the medium are good, you can mount

VEGAPULS 61 on sockets which are higher than the length of the

antenna. You will find recommended values for socket heights in the

following illustration. The socket end should be smooth and burr-free,

if possible also rounded. After installation you must carry out a false

echo storage.

d

h

d

h

1½"

50 mm/2"

80 mm/3"

100 mm/4"

150 mm/6"

200 mm

250 mm

300 mm

500 mm

800 mm

Fig. 16: Deviating socket dimensions

Align the sensor in liquids as vertical as possible to the product sur-

face to achieve optimum measurement.

Fig. 17: Alignment in liquids

The mounting location of the radar sensor should be a place where no

other equipment or fixtures cross the path of the microwave signals.
Vessel installations, such as e.g. ladders, limit switches, heating spi-

rals, struts, etc., can cause false echoes and impair the useful echo.

Socket with encapsulated

antenna system

Sensor orientation

Vessel installations

Advertising