VEGA KV 31 Mounting brackets For tubes with ø 50…200 mm (Vertical sensor mounting) User Manual

Page 6

Advertising
background image

7

6

5

4

1

8

3

2

A

Fig. 3: Mounting bracket with vertically mounted sensor

1

Threaded rod M10 x 360 mm - 4 pieces

2

Hexagon nut M16 - 4 pcs.

3

Hexagon nut M10 - 16 pcs.

4

Washer for M16 - 4 pieces

5

Clamp - Source holder side (VEGASOURCE 31) - 1 piece

6

Washer for M10 - 8 pieces

7

Hexagon screw M8 - 2 pieces

8

Clamp - Sensor side (MINITRAC) - 1 piece

A

Arrow cutout of the clamp and the lug point in the same direction

1

Make sure that the two clamps (5 and 8) of the bracket are in
parallel. Do this by measuring the lateral distances between the
clamps.

2

Tighten the nuts of the threaded rod evenly. Keep the tube
diameter and the stability of the tube material in mind. Avoid
deformation of the tube through an overtightening of the mounting
bracket.

If you have the impression that the tube cannot permanently carry
the weight of the mounting bracket, sensor and source container,
mount a suitable support below the mounting bracket.

6

Mounting brackets KV 31 • Source holder SE

2 Mounting

38482

-EN

-120228

Advertising