VEGA VEGAFLEX series 80 Rod and cable components User Manual

Page 10

Advertising
background image

10

2 Mounting

Rod and cable components • for VEGAFLEX series 80

44968-EN-131107

2.2 Rod extension - ø 12 mm (0.47 in)

Basic rod - ø 12 mm (0.47 in)

To mount the measuring rod, you need a size 10 wrench.

A

M6

ø12 mm

(0.47")

Fig. 8: Rod components - ø 12 mm (0.47 in) - basic extension rod
A Basic extension rod with ø 12 mm (0.47 in)

1. Loosen the rod with a fork wrench applied to the flat surface,

provide counterforce with another fork wrench.

2. Screw out the loosened measuring rod by hand.
3. Apply a small amount of acid-free grease to the thinner neck of

the base rod.

4. Insert the new measuring rod carefully by hand with a screwing

motion into the opening of the process fitting.

5. Continue screwing in the rod manually into the opening of the pro-

cess fitting.

6. Exert counterforce with a fork spanner on the hexagon of the pro-

cess fitting and tighten the rod on the flat surfaces with a second

fork spanner (SW 10) with a torque of 10 Nm (7.37 lbf ft).

Tip:

Please maintain the specified torque so that the max. tensile strength

remains.

Advertising