2 mounting, 1 general instructions – VEGA VEGAFLEX series 80 Rod and cable components User Manual

Page 6

Advertising
background image

6

2 Mounting

Rod and cable components • for VEGAFLEX series 80

44968-EN-131107

2 Mounting

2.1 General instructions

Make sure that there is a distance of at least 300 mm (11.81 in.)

between the rod of the probe and the vessel wall.

≥ 300 mm

(11.81")

150 mm

(5.91")

150mm (5.91"

)

1

SW 13

L

Fig. 3: Min. distance from the vessel wall
1 Upper measuring range end

L Length of the extension rod

Please note that the order length of the probe extension deviates from

the actual length. You can see the order length of the probe in the

following illustration.
With a flange version, the probe length refers to the sealing surface of

the flange, with threaded fittings to the sealing edge of the thread.

Distance to the vessel

wall

Measurement length - ex-

tensions VEGAFLEX 81

Advertising