11 Supplement

VEGAFLEX 82 • Foundation Fieldbus

44221-EN-130910

m(d)

%

Lin%

Primary

Value

Secondary

Value 2

Secondary

Value 1

TB

Sensor_Value

min/max

adjustment

Linearization

Fig. 63: Schematic presentation Transducer Block (TB)

Function block Analog Input (AI)
The function block "Analog Input (AI)" takes the original measured value selected by a Channel

Number and makes it available to additional function blocks on its output.

Fig. 64: Schematic presentation function block Analog Input (AI)

Function block Discret Input (DI)
The function block "Discret Input (DI)" takes the original measured value selected by a Channel

Number and makes it available to additional function blocks on its output.

Fig. 65: Schematic presentation function block Discret Input (DI)