VEGA VEGABAR 86 HART and accumulator pack - Operating Instructions User Manual

Page 52

Advertising
background image

52

10 Supplement

VEGABAR 86 • HART and accumulator pack

45040-EN-131107

Process conditions
Product temperature depending on the measuring cell seal
The specifications are an overview. The specification on the type plate are valid.

Version

Measuring cell seal

Product temperature

Suspension cable PE

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +60 °C (-4 … +140 °F)

Suspension cable PUR

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +80 °C (-4 … +176 °F)

Suspension cable FEP

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +100 °C (-4 … +212 °F)

FFKM (Kalrez 6375)

-10 … +100 °C (+14 … +212 °F)

Connection tube

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +100 °C (-4 … +212 °F)

FFKM (Kalrez 6375)

-10 … +100 °C (+14 … +212 °F)

Transmitter material PVDF

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +60 °C (-4 … +140 °F)

FFKM (Kalrez 6375)

-10 … +60 °C (+14 … +140 °F)

Transmitter protection PE

FKM (VP2/A)
EPDM (A+P 75.5/KW75F)

-20 … +60 °C (-4 … +140 °F)

Mechanical stress, depending on the instrument version
Vibration resistance

Ʋ Suspension cable

4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Ʋ Connection tube

1 g (with lengths > 0.5 m (1.64 ft), the tube must be sup-

ported in addition)

Shock resistance

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry

Ʋ Cable gland

M20 x 1.5

Ʋ Cable diameter (options)

5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)

Ʋ Cable entry

½ NPT

Ʋ Blind plug

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Signal circuit

Plug M12 x 1, according to ISO 4400, Harting HAN,

7/8" FF

Ʋ Indication circuit

M12 x 1 plug

Advertising