3 Mounting

VEGABAR 52 • with small flange 4 x M5 and extension tube ø 42 mm

45008-EN-130417

3 Mounting

3.1 Mounting preparations

The following tools are required for mounting:

Allen wrench size 4

3.2 Mounting steps

Proceed as follows:
1. Remove protective cap from the process fitting
2. Insert process seal into the groove on the process fitting

1

2

Fig. 1: Insert process seal
1 Groove on the process fitting

2 Process seal

3. Insert extension into the mounting boss. The process seal must

keep its position

4. Screw in all mounting screws and tighten evenly. For the required

torque, see chapter "Technical data"

Warning:

The VEGABAR 52 may be pressurized only when all four mount-

ing screws are tightened as described. Only the supplied mounting

screws may be used.
Otherwise, the process seal and the pressure holding capacity of the

process fitting are not guaranteed. Personal injury and/or property

damage can result.

Assembly is finished.