Hexfred, Ultrafast soft recovery diode, 70 a, Vishay semiconductors – C&H Technology VS-HFA70EA120 User Manual

Page 2

Advertising
background image

VS-HFA70EA120

www.vishay.com

Vishay Semiconductors

Revision: 20-Jul-12

1

Document Number: 94747

For technical questions within your region:

[email protected]

,

[email protected]

,

[email protected]

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT

ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT

www.vishay.com/doc?91000

HEXFRED

®

Ultrafast Soft Recovery Diode, 70 A

FEATURES

• Fast recovery time characteristic

• Electrically isolated base plate

• Antiparallel diodes

• Large creepage distance between terminal

• Simplified mechanical designs, rapid assembly

• Designed and qualified for industrial level

• UL approved file E78996

• Material categorization: For definitions of compliance

please see

www.vishay.com/doc?99912

DESCRIPTION/APPLICATIONS

This SOT-227 modules with HEXFRED

®

rectifier are in

antiparallel configuration. The antiparallel configuration is
used for simple series rectifier and high voltage application.
The semiconductor in the SOT-227 package is isolated from
the copper base plate, allowing for common heatsinks and
compact assemblies to be built.
These modules are intended for general applications such
as HV power supplies, electronic welders, motor control and
inverters.

PRODUCT SUMMARY

V

R

1200 V

V

F

(typical)

2.2 V

t

rr

(typical)

48 ns

I

F(DC)

at T

C

, per module

70 A at 121 °C

SOT-227

ABSOLUTE MAXIMUM RATINGS

PARAMETER

SYMBOL

TEST CONDITIONS

MAX.

UNITS

Cathode to anode voltage

V

R

1200

V

Continuous forward current, per leg

I

F

T

C

= 121 °C

35

A

Single pulse forward current

I

FSM

T

J

= 25 °C

350

Maximum power dissipation, per leg

P

D

T

C

= 25 °C

357

W

T

C

= 100 °C

143

RMS isolation voltage

V

ISOL

Any terminal to case, t = 1 minute

2500

V

Operating junction and storage
temperature range

T

J

, T

Stg

- 55 to + 150

°C

ELECTRICAL SPECIFICATIONS (T

J

= 25 °C unless otherwise specified)

PARAMETER

SYMBOL

TEST CONDITIONS MIN.

TYP.

MAX.

UNITS

Cathode to anode
breakdown voltage

V

BR

I

R

= 100 μA

1200

-

-

V

Forward voltage, per leg

V

FM

I

F

= 30 A

-

2.2

3.0

I

F

= 60 A

-

2.8

4.0

I

F

= 30 A, T

J

= 125 °C

-

2.13

-

I

F

= 60 A, T

J

= 125 °C

-

2.70

-

I

F

= 30 A, T

J

= 150 °C

-

2.04

-

I

F

= 60 A, T

J

= 150 °C

-

2.65

-

Reverse leakage current, per leg

I

RM

V

R

= V

R

rated

-

2.0

75

μA

T

J

= 125 °C, V

R

= V

R

rated

-

1.6

5

mA

T

J

= 150 °C, V

R

= V

R

rated

-

5

10

Advertising