5

VSK.166, .196, .236..PbF Series

Standard Recovery Diodes, 165 A to 230 A

(New INT-A-PAK Power Modules)

Vishay High Power Products

Fig. 9 - On-State Power Loss Characteristics

Fig. 10 - Current Ratings Characteristics

Fig. 11 - Current Ratings Characteristics

Fig. 12 - On-State Power Loss Characteristics

Fig. 13 - On-State Power Loss Characteristics

0

800

600

400

200

1600

1400

1200

1000

Maximum Total Power Loss (W)

Total Output Current (A)

100

200

300

400

500

0

120°

(Rect)

3 x VSK.166.. Series

Three phase bridge

Connected

T

J

= 150 °C

-

~

0

400

200

800

600

1600

1400

1200

1000

Maximum Total Power Loss (W)

Maximum Allowable Ambient

Temperature (°C)

25

50

75

100

125

150

0

0.04 K/

W

0.06 K/

W

0.1 K/

W

0.16 K/

W

0.25 K/

W

0.5 K/

W

R

thSA

= 0.02 K/

W

- Δ

R

70

100

110

120

130

140

150

90

80

Maximum Allowable Case

Temperature (°C)

Average Forward Current (A)

50

100

150

200

250

0

30°

60°

90°

120°

180°

VSK.196.. Series
R

thJC

(DC) = 0.16 K/W

Ø

Conduction angle

70

100

110

120

130

140

150

90

80

Maximum Allowable Case

Temperature (°C)

Average Forward Current (A)

50

100

150

200

250

350

300

0

DC

30°

60°

90°

120°

180°

VSK.196.. Series
R

thJC

(DC) = 0.16 K/W

Ø

Conduction period

0

200

250

300

150

100

50

Maximum Average Forward

Power Loss (W)

Average Forward Current (A)

40

80

120

160

200

0

RMS limit

180°
120°

90°
60°
30°

VSK.196.. Series
T

J

= 150 °C

Conduction angle

Ø

0

300

350

250

200

150

100

50

Maximum Average Forward

Power Loss (W)

Average Forward Current (A)

50

100

150

200

250

300

350

0

DC

180°
120°

90°
60°
30°

RMS limit

VSK.196.. Series

Per junction
T

J

= 150 °C

Ø