Vishay high power products – C&H Technology VSK.236..PbF Series User Manual

Page 8

Advertising
background image

Document Number: 94357

For technical questions, contact: [email protected]

www.vishay.com

Revision: 22-Apr-08

7

VSK.166, .196, .236..PbF Series

Standard Recovery Diodes, 165 A to 230 A

(New INT-A-PAK Power Modules)

Vishay High Power Products

Fig. 18 - On-State Power Loss Characteristics

Fig. 19 - Current Ratings Characteristics

Fig. 20 - Current Ratings Characteristics

Fig. 21 - On-State Power Loss Characteristics

Fig. 22 - On-State Power Loss Characteristics

800

600

400

200

0

1800

1600

1400

1200

1000

Maximum Total Power Loss (W)

Total Output Current (A)

200

100

300

400

500

600

0

120°

(Rect)

3 x VSK.196.. Series

Three phase bridge

Connected

T

J

= 150 °C

+

-

~

0

800

600

400

200

1800

1600

1400

1200

1000

Maximum Total Power Loss (W)

Maximum Allowable Ambient

Temperature (°C)

50

25

75

100

150

125

0

0.04 K/

W

0.06 K/

W

0.0

8 K/

W

0.12 K/

W

0.16 K/

W

0.25 K/

W

0.4 K/

W

R

thSA

= 0.12 K/

W

- Δ

R

130

140

150

160

120

110

100

90

80

Maximum Allowable Case

Temperature (°C)

Average Forward Current (A)

50

100

150

200

250

0

VSK.236.. Series
R

thJC

(DC) = 0.14 K/W

Ø

Conduction angle

180°

90°

120°

60°

30°

130

140

150

120

110

100

90

80

70

Maximum Allowable Case

Temperature (°C)

Average Forward Current (A)

50

100

150

200

300

250

350

400

0

DC

VSK.236.. Series
R

thJC

(DC) = 0.14 K/W

Ø

Conduction period

120°

180°

90°

60°

30°

0

250

300

350

200

150

100

50

Maximum Average Forward

Power Loss (W)

Average Forward Current (A)

50

100

150

200

250

0

RMS limit

180°
120°

90°
60°
30°

VSK.236.. Series
T

J

= 150 °C

Conduction angle

Ø

0

350

400

450

300

250

200

150

100

50

Maximum Average Forward

Power Loss (W)

Average Forward Current (A)

50

100

150

200

300

250

350

400

0

DC

180°
120°

90°
60°
30°

RMS limit

VSK.236.. Series

Per junction
T

J

= 150 °C

Ø

Conduction period

Advertising