12. TROUBLESHOOTING

Cleaning the Body of the laminator

To clean the machine body, dampen a cloth with water only and gently wipe the

machine clean.

Removing Adhesive Build Up

1. Remove the film from the laminator.

2. Use a damp (water only) cloth and a rubber gum eraser to remove

the adhesive on the Teflon (metal) and silicone rollers.

Symptom

Machine will

not turn on:

There is power, but the
rollers are not turning
after the "RUN" button is
pressed:

The unit is not heating up

Curled lamination:

Unclear lamination:

Cause

a. Power switch is in "0"

(Off) position

b. Tripped circuit breaker.
c. Blown main power fuse.

a. Safety cover is not closed.
b. Paper guide is not installed

correctly.

c. Blown motor fuse.

a. The machine is in "COLD"

mode.

b. Set temperature is lower

than the room temperature.

a. Upward curl.
b. Downward curl.

The main roller temperatures
are too low and/or lamination
speed is too fast.

Possible Solution

a. Put the power switch to

the "I" (On) position

b. Reset the circuit breaker.
c. Replace the fuse.
a. Close the safety cover to

active the safety switch.

b. Properly install the paper

guide so that the micro
switch is activated.

c. Replace the motor fuse.
a. Switch to "HOT" mode.
b. Raise the temperature

according to the
recommended film
temperature.

a. Loosen the top roll film

tension.

b. Loosen the bottom roll

film tension.

Raise the roller
temperatures and/or
lower the lamination speed.

NOTE: Rub firmly but do not scrub the rollers vigorously as this may
scratch the surface. Do not use sharp metal objects, steel wool,
or abrasive, as these may also damage the rollers.

11. MAINTENANCE