Axles cab service refill capacities, Tires, Sound – Milton CAT 966K User Manual

Page 15

Advertising
background image

Axles

Cab

Service Refill Capacities

Front

Fixed

Rear

Oscillating
±13 degrees

Maximum Single­

495 mm

19.5 in

Wheel Rise and Fall

Tires

• Choose from a variety of tires to match

your application.

• Choices include:

26.5R25 VLT BS E3 Radial
26.5R25 VJT BS E3/L3 Radial
26.5R25 VMT BS L3 Radial
26.5­25 SRG LD FS L3 Bias
750/65R25 XLD L3T MX L3 Radial
26.5R25 XHA2 MX L3 Radial
26.5R25 XLD D1 MX L4 Radial
26.5R25 VSNT BS E4/L4 Radial
26.5­25 SDT LD FS L5 Bias
26.5R25 VSDL BS L5 Radial
26.5R25 XLDD2 MX L5 Radial
26.5R25 X MINE D2 MX L5 Radial
Cat Flexport™

• NOTE: In certain applications (such as

load and carry), the loader’s productive
capabilities might exceed the tires’ tonnes­
km/h (ton­mph) capabilities. Caterpillar
recommends that you consult a tire supplier
to evaluate all conditions before selecting a
tire model. Other special tires are available
on request.

ROPS/FOPS

Meets SAE and

ISO standards

• Cat cab with a four post integrated Rollover

Protective Structure (ROPS) are standard in
North America and Europe.

• ROPS meets SAE J1040 APR88 and

ISO 3471:1994 criteria.

• Falling Objects Protective Structure (FOPS)

meets SAE J231 JAN81 and ISO:1992
Level II criteria.

Sound

• The sound values indicated below are

for specific operating conditions only.
Machine and operator sound levels will
vary at different engine and/or cooling fan
speeds. Hearing protection may be needed
when the machine is operated with a cabin
that is not properly maintained, or when
the doors and/or windows are open for
extended periods or in a noisy environment.

• The operator sound pressure level for a

standard machine confi guration, measured
according to the procedures specifi ed in
ISO 6396:2008, is 71 dB(A) with the
cooling fan speed set at maximum value.

• The machine sound power level for a

standard machine confi guration, measured
according to the procedures specifi ed in
ISO 6395:2008, is 111 dB(A) with the
cooling fan speed set at maximum value.

• The machine sound pressure level for

a standard machine confi guration,
measured according to the procedures
specified in SAE J88:2006, is 76 dB(A).
The measurement was conducted under
the following conditions: distance of 15 m
(49.2 ft), moving forward in an intermediate
gear ratio, static hydraulic cycle (with no
payload) and with the cooling fan speed
set at maximum value.

• The operator sound pressure level for

a machine installed with a Low Sound
package, measured according to the
procedures specified in ISO 6396:2008,
is 69 dB(A) with the cooling fan speed
set at maximum value.

• The machine sound power level for a

machine installed with a Low Sound
package, measured according to the
procedures specified in ISO 6396:2008,
is 108 dB(A) with the cooling fan speed
set at maximum value.

Fuel Tank –

381 L

101 gal

Standard

Cooling System

65 L

17.2 gal

Crankcase

24.5 L

6.5 gal

Transmission

50 L

13.2 gal

Differentials and

64 L

16.9 gal

Final Drives – Front

Differentials and

64 L

16.9 gal

Final Drives – Rear

Hydraulic Tank

198 L

52.3 gal

15