©Velleman nv



Closed-loop mode







Low Power
When the power voltage is low, the display will show LOP. Please check your power supply. LOP may appear

briefly just after you have turned the device on. Pay no attention to this, it’s normal.

MIDI Run
If no MIDI data are received for ten minutes, the device goes to standby mode.
You need to enter the device ID (= 55H) in order to send or receive a file. You can add scenes to the memory

or call them up and you can exchange information with a device that is connected to your device.
This unit sends or receives NOTE information as follows:

Note number

Velocity

Function

22 – 69

Programme Master

Turn on/off programme 1 - 48

70 – 93

Channel Dimmer

Turn on/off channel 1 – 24

94

FULL-ON

95

DARK

96

HOLD

97

Turn on/off audio chase

98

CHASE / SCENES mode

99

DOUBLE PRESET mode

100

SINGLE PRESET mode

101

Step change

102

BLACK OUT

Switch the display between 0-100% and 0-255
1.
Hold the RECORD button.
2. Press the % OR 0-255 key.
3. Release the RECORD button.

11. Cleaning and Maintenance

All screws for installing the devices or parts of the device have to be screwed down tight and must not be

corroded.

The housing, mounting supports and connections should not be modified or tampered with e.g. do not drill

extra holes in mounting supports, do not change the location of the connections, etc.

The electric power supply cables must be undamaged. Have the device installed by a qualified technician.

Disconnect the device from the mains prior to maintenance activities.

Wipe the device regularly with a moist cloth. Do not use alcohol or solvents.

Entrust a qualified technician with the maintenance of this device. Contact your dealer for spare parts if