Layout, Scope of use, Assembly and starting – Stanley D 200/8/6 User Manual

Page 15: 1 fitting the wheels (pic. 3 ÷ 4), 2 fitting the supporting foot (ref. 4), 3 voltage

Advertising
background image

15

G

B

safety.

● When fitting a tool, the flow of air in output must

be switched off.

● When using compressed air, you must know and

comply with the safety precautions to be adopted

for each type of application (inflation, pneumatic

tools, painting, washing with water-based

detergents only, etc.).

2. LAYOUT

1. Shroud

2. Pressure vessel

3. Wheel

4. Supporting foot

5. Quick-lock coupling (regulated compressed air)

6. Pressure gauge (for reading the preset

pressure by means of regulator)

7. Pressure regulator

8. ON/OFF switch

9. Transportation handle

10. Safety valve

11. Receiver condensation drainage tap

12. Pressure gauge (for reading the tank pressure)

13. Axle

14. Clip

15. Bolt

16. Nut

17. Washer

3. SCOPE OF USE

The compressor is designed for generating

compressed air for tools operated by compressed

air.

Please note that our equipment has not been

designed for use in commercial, trade or industrial

applications. Our warranty will be voided if the

machine is used in commercial, trade or industrial

businesses or for equivalent purposes.

The machine is to be used only for its prescribed

purpose. Any other use is deemed to be a case of

misuse. The user/operator and not the manufacturer

will be liable for any damage or injuries of any kind

caused as a result of this.

4. POINTS TO NOTE

WHEN SETTING UP THE

COMPRESSOR

● Examine the machine for signs of transit damage.

Report any damage immediately to the company

which delivered the compressor.

● The compressor should be set up near the

working consumer.

● Avoid long air lines and long supply lines

(extensions).

● Make sure the intake air is dry and dust-free.

● Do not set up the compressor in damp or wet

rooms.

● The compressor may only be used in suitable

rooms (with good ventilation and an ambient

temperature from +5°C to +40°C). There must

be no dust, acids, vapors, explosive gases or

inflammable gases in the room.

● The compressor is designed to be used in dry

rooms. It is prohibited to use the compressor

in areas where work is conducted with sprayed

water.

5. ASSEMBLY AND STARTING

Warning!

You must fully assemble the appliance before

using it for the first time.

5.1 Fitting the wheels (Pic. 3 ÷ 4)

Fit the supplied wheels as shown in Pic. 3 & 4:

● Pic.3a & 3b: Assembly of wheel kit - version A

Assembly by sequence: a, b, c, d, e

● Pic.4a & 4b: Assembly of wheel kit - version B

5.2 Fitting the supporting foot (ref. 4)

Fit the supplied rubber stopper as shown in Pic. 5.

5.3 Voltage

The compressor is equipped with a mains cable

with shock-proof plug. This can be connected to any

230V ~ 50Hz shock-proof socket which is protected

Advertising