3 safety valve (ref. 10), 4 storage, Disposal and recycling – Stanley D 200/8/6 User Manual

Page 17: Possible faults and related permitted remedies

Advertising
background image

17

G

B

compatible manner at the appropriate collection

point.

6.3 Safety valve (ref. 10)

The safety valve has been set for the highest

permitted pressure of the pressure vessel. It is

prohibited to adjust the safety valve or remove its

seal. Actuate the safety valve from time to time to

ensure that it works when required. Pull the ring with

sufficient force until you can hear the compressed

air being released. Then release the ring again.

6.4 Storage

Warning!

Pull the mains plug out of the socket and

ventilate the appliance and all connected

pneumatic tools.

Switch off the compressor and make sure that it

is secured in such a way that it cannot be started

up again by any unauthorized person.

Warning!

Store the compressor only in a dry location which

is not accessible to unauthorized persons.

Always store upright, never tilted!

7. DISPOSAL AND RECYCLING

The unit and its accessories are made of various

types of material, such as metal and plastic.

Defective components must be disposed of as

special waste. Ask your dealer or your local

council.

8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES

FAULT

CAUSE

REMEDY

Leakage of air from the valve

of the pressure switch with

the compressor off.

Check valve that, due to wear

or dirt on the seal, does not

perform its function correctly.

Unscrew the hexagonal head

of the check valve, clean the

valve seat and the special

rubber disk (replace if worn).

Reassemble and tighten

carefully.

Reduction of performance.

Frequent start-up. Low

pressure values.

Excessive performance

request, check for any leaks

from the couplings and/or

pipes. Intake filter may be

clogged.

Replace the seals of the

fitting, clean or replace the

filter.

The compressor stops and

restarts automatically after a

few minutes.

Tripping of the thermal cutout

due to overheating of the

motor.

Clean the air ducts in the

conveyor. Ventilate the work

area.

After a few attempts to

restart, the compressor.

Tripping of the thermal cutout

due to overheating of the

motor (removal of the plug

with the compressor running,

low power voltage).

Activate the on/off switch.

Ventilate the work area.

Wait a few minutes. The

compressor will restart

independently.

The compressor does not

stop and the safety valve is

tripped.

Irregular functioning of the

compressor or breakage of

the pressure switch.

Remove the plug and contact

the Service Center.

Any other type of operation must be carried out by authorized Service Centers, requesting

original parts. Tampering with the machine may impair its safety and in any case make the

warranty null and void.

Advertising