APPENDIX 6 PIN CONFIGURATION

62

For 8CH Model

* The D-Sub connector shown above is optional.

Siren:

When the DVR is triggered by alarm or motion, the
COM connects with NO and the siren with strobe
starts wailing and flashing.

Magnetic Contact:

When the magnetic contact is opened, the alarm
will be triggered and the recording is on.

PIN

FUNCTION

DESCRIPTION

1

GND GROUND

2~5

ALARM INPUT

Connect ALARM INPUT (PIN 2 – 5) and GND (PIN 1) connector with

wires. Once an alarm is triggered, the DVR will start recording and the
buzzer will be on.

PIN Alarm

Corresponding

video

channel

PIN 2

1

CH1

PIN 3

3

CH3

PIN 4

5

CH5

PIN 5

7

CH7

*

6 ~ 11

PIN OFF

NA

12

RS485-A

13

EXTERNAL ALARM NO.

Under the normal operation, COM disconnects with NO. But when any

alarm is triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.

14

PIN OFF

NA

15~18

ALARM INPUT

Connect ALARM INPUT (PIN 15 – 18) and GND (PIN 1) connector with

wires. Once an alarm is triggered, the DVR will start recording and the
buzzer will be on.

PIN

Alarm

Corresponding video channel

PIN 15

2

CH2

PIN 16

4

CH4

PIN 17

6

CH6

PIN 18

8

CH8

*

19~23

PIN OFF

NA

24

RS485-B

25

EXTERNAL ALARM

COM

Under the normal operation, COM disconnects with NO. But when any

alarm is triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.