PNEG-1550 Belt Guard

13

Installation

c. The Horizontal Drive on 8'' Double-Drive Vertical Augers requires disassembling the

Motor Mount components to remove/replace the Belt Guard Brackets.

i. After the motor has been removed, loosen the 3/4'' Hex nut underneath the

Motor Mount Sides, holding down the Motor Mount Assembly.

Motor Mount

Sides

3/4'' Hex
Nut

Motor Mount
Assembly

Figure 4C

ii. Remove the Motor Mount Assembly.

iii. Unbolt the four (4) 1/2'' x 1'' Hex bolts, lock washers, and Hex nuts, and remove

the existing Belt Guard Brackets.

Motor Mount
Sides

Lock Washer

Hex Nuts

1/2'' x 1'' Hex Bolts

Belt Guard
Brackets

Figure 4D