Eave heights greater than 40' 5 – Grain Systems Bin Accessories PNEG-1810 User Manual

Page 33

Advertising
background image

PNEG-1810 Bin Manager Temperature Cable Support Bracket Instructions

33

7. Temperature cable support packages for eave height greater than 40' 5"

Eave Heights Greater than 40' 5"

1. All 27' through 36' packages shall span one roof panel.

2. A rafter support system will be necessary for temperature cable installation in commercial tanks

27' through 36' in diameters that have an eave height of greater than 40' 4".

3. All packages include hanging angle and cable support channel.

4. Each set of rafters should carry only one temperature cable.

5. If it is desired to support the cable from the flange of the support channel, it will be necessary to

reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.

6. No more than one cable should be supported from a pair of roof rafters.