Wind ring and access door assembly, Chapter 5 wind ring and access door assembly, Wind ring assembly – Grain Systems Tanks PNEG-1400 User Manual

Page 43

Advertising
background image

PNEG-1400 WCL Commercial 4" Corrugation Externally Stiffened Grain Bin

43

5. Wind Ring and Access Door Assembly

Wind Ring Assembly

Figure 5A

1. To connect wind ring pipe to the stiffeners, attach with 3/8" x 1" bolts through the flange of the

stiffener. Field drilling of wind ring locations may be required in some cases.

2. Attach wind ring pipe section to stiffener using two (2) 3/8" x 6" (S-7248) wind ring clamps.

3. Place pipes end to end without overlapping. Fasten together using two (2) wind ring couplers

and six (6) 3/8" x 1" flanged head bolts with flanged nuts. Couplers should be centered on the
seam of pipes.

Figure 5B

Advertising